One platform.One workspace.Total collaboration, all hands
Ten live sources composited side by side, true wireless BYOM on the room's own camera an' mic, an' sharin' that crosses networks — no VPN, no cable on the table, savvy.
Live sources composited side by side, compared, annotated, rearranged live, up to the published per-tier ceilin': 5 on Essentials, 10 on Pro. The room's own silicon does the heavy haulin'; nobody's laptop be load-bearin'.
On every Polaris tier, Pro included: guests on LTE, staff on the corp Wi-Fi, the display on an AV VLAN, one workspace, no VPN, no UC call. Eleven o' the twelve competitors we checked in August 2026 document LAN-local media only, on their own published specifications; one o' them says it plainly: users on a cellular network or guest Wi-Fi cannot use it. The vendor list an' the sources be charted on the architecture page an' the compare matrix.
The device be tested too, by another crew entirely.
Certifications scoped to a cloud say nothin' about the box on the wall, so the box gets its own proof. Two outside crews have had at it: one over the network, one with the lid off.
Independent scan by an outside crew · July 2026
No network attack surface worth the name, matey
An outside firm scanned a managed Pod. The ports that answer be the castin' and appliance functions, and no persistent media listener was enumerable at all, the real-time media path uses ephemeral per-session UDP ports that answer only after ICE consent. There be no standin' media service in the room to probe.
Independent physical attack by an outside crew · May 2025
Opened, probed, an' it held fast
An outside firm took a Gen 4 Pod in hand, opened it an' attacked the hardware: UART an' JTAG on the debug headers, an attempt to lift the firmware off the flash, a lab man-in-the-middle. No critical, high, medium or low-severity vulnerabilities were identified. Root login over the debug interface be refused outright, with no password prompt even offered; the firmware could not be extracted; no personally identifiable information was found stowed on the device; an' a presented invalid certificate was refused: the Pod failed the handshake an' stopped talkin' to Mersive rather than trustin' the interceptor.
Aboard the device
Secure boot, sealed keys, an allowlist an' 802.1X
Secure boot be mandatory on production firmware. The device's own identity keys be sealed into an NXP SE050 secure element. USB access be by allowlist. 802.1X with EAP-TLS makes the room a first-class citizen o' yer NAC rather than an exception in it.
The company, an' the cloud
ISO/IEC 27001:2022 · SOC 2 Type 2
Mersive be ISO/IEC 27001:2022 certified, with no nonconformities raised at the June 2026 surveillance audit, and the Polaris cloud this Pro unit reports to be SOC 2 Type 2 attested.
Their caveat, which we keep: that does not make compromise impossible, but it would take an adversary o' significant skill and effort. The full architecture, every scope statement and the audit findin's: the Trust Center.
Open specs: nothin' gated
The spec sheet, laid out inline.
Full transparency, matey: the full network an' security posture laid out on the page, with no form between ye an' the facts.
Sharin'4 rows ▾
Specification
Polaris Pro
Simultaneous shares aboard the workspace
Polaris Pro can currently carry up to 10 live sources composited side by side
Web-join from the browser: no app, no download, no fuss
✓ share from the device ye walked in with
Native AirPlay · Miracast · Google Cast (LAN)
✓ all three, built in: cast from Apple, Windows and Chromebook devices on the room network with nothin' installed
Mobile sharin' · phones an' tablets
✓ the Polaris app fer iOS and Android: share yer screen, photos or a live whiteboard, and steer the workspace from yer seat
Network3 rows ▾
Specification
Polaris Pro
802.1X network authentication
✓ EAP-TLS, PEAP, TTLS or EAP-PWD, on wired Ethernet and on Wi-Fi (WPA2-Enterprise). Supply a CA certificate, a client certificate and a private key; the supplied private key be held encrypted at rest under a key that is itself sealed in the NXP SE050 secure element, rather than in plaintext configuration
Dual-network posture: corp + guest, kept isolated
Wired GbE an' the wireless radio run at the same time, an' the pod does not forward between them: its firewall drops all forwarded traffic an' the firmware never enables IP forwardin'. Corporate on the wire, guests on Wi-Fi — kept apart because the device be not a router, not because o' a policy someone could unmake
Cross-network relay: subnets / VLANs / the open internet
✓ cloud-negotiated direct connections; signalin' be outbound-only TLS on TCP 443; no inbound firewall rules needed
Plain speakin': 802.1x means the network itself demands the device prove who it be before grantin' a port; EAP-TLS proves it with a certificate instead o' a password. Dual-network posture means the device sits on two networks at once, kept isolated, so guests share without ever settin' foot on the corporate LAN.
Security8 rows ▾
Specification
Polaris Pro
Encryption on the voyage (in transit)
Signallin' an' fleet management run outbound over HTTPS to Polaris Cloud. The device exposes no TLS listener of its own, so a port scan o' the pod finds nothin' to negotiate against — the encryption that matters be on the outbound leg o' the voyage, not on an open port in yer room
Secure boot · a secure element
✓ secure boot be mandatory on production firmware an' is rooted in Trusted Firmware-A (TF-A); the NXP SE050 secure element on board holds the device's own identity an' update-verification keys in hardware
A TAA-compliant supply chain
✓ built with Advantech in Taiwan, a TAA-designated country, with the bare printed circuit board the only China-sourced item aboard the build
Linux-hardened OS
✓ purpose-built, minimized Linux at the display: no Windows attack surface, no general-purpose desktop, savvy
Key custody: where the private keys be stowed
✓ device private keys be generated an' used inside the NXP SE050 secure element an' never cross its boundary. The channel between the application an' the secure element be itself authenticated an' encrypted (GlobalPlatform SCP-03), an' the keys fer that channel be held in ARM TrustZone secure firmware where neither the operatin' system nor any application can read them.
Signed updates, no downgrade — an' automatic rollback on a failed load
✓ two different things, an' both matter. Update packages be checked fer authenticity an' integrity before they be applied, an' the device will not accept a downgrade to an earlier version, so a known-vulnerable firmware cannot be pushed back onto a Pod. Separately, the pod keeps two firmware partitions: a new image installs alongside the runnin' one rather than over it, an' a pod that fails to come up on the new version comes back up on the last known-good one. Deliberate downgrade be refused; a bad load rights itself.
Content that never lingers aboard
✓ shared content be composited on the fly rather than written to the device, an' ephemeral session data — content, session keys an' generated random values — be overwritten at the end o' every session, includin' sessions that be abandoned rather than ended cleanly.
Physical: a Kensington Nano Security Slot
✓ on the hull
I/O7 rows ▾
Specification
Polaris Pro
HDMI output: twin displays
2× HDMI 2.0, twin 4K (3840 × 2160) at 60 Hz; 1080p an' 720p up to 60 Hz. CEC fer display power an' input control, savvy
HDMI input: ingest by cable / room-system augmentation
1× HDMI 2.0 in, 1280 × 720 through 4K (3840 × 2160) at up to 60 Hz, with HDCP 2.0 content protection. Polaris Pro has two wired HDMI input modes, chosen by yer room administrator. Workspace tile be the default: the input joins the workspace alongside wireless shares and be visible to remote crewmates. Direct bypass (full-screen pass-through) sends the input straight to the room display, outside the workspace. Remote crewmates do not receive that feed.
Ethernet
1× 10/100/1000 RJ-45, PoE+ (802.3at Type 2)
Audio out
✓ a dedicated analog audio-out jack on the rear panel, so room audio can go straight to a soundbar or a DSP without passin' through the display
USB: yer peripherals (camera, mic, speaker, touch)
2× USB 3.0+ Type-C (female), in host mode · output 5 V at 0.9 A maximum · no USB Power Delivery — this be what carries a room camera an' mic fer wireless BYOM. lists the port count only, without a generation or connector type, so the sheet be less specific than the requirement rather than in conflict with it.
Compute: the silicon below decks, behind the workspace4 rows ▾
Specification
Polaris Pro
Chipset / SoC
MediaTek MT8395AV/ZA (Genio 1200): 8-core ARM, 4× Cortex-A78 an' 4× Cortex-A55 at up to 2.2 GHz, with a Mali GPU and on-die APU (MediaTek's name fer its NPU), OpenGL ES 3.0 / Vulkan.
NPU: AI silicon aboard the device
NPU 4.8 TOPS (INT8) in the MediaTek documentation, 9.6 TOPS at minimum precision (INT4), the convention MediaTek uses fer its current Genio series.
RAM · storage
16 GB LPDDR4 · 32 GB eMMC: 19 GB available fer storage, the remainder holdin' the system image and the second partition that carries an OTA update and allows firmware rollback
Video pipeline: simultaneous decodin' / real-time encodin'
Decode 2× 4K60 or 4× 1080p60 at once; the compositor imposes no cap at the layout layer; the published Pro ceilin' be 10 simultaneous shares, set by decode throughput
Power & physical form4 rows ▾
Specification
Polaris Pro
Power
PoE+ (802.3at Type 2) fer a single-cable install, or 12 VDC, 2 A, 24 W max from the barrel jack. The power supply be sold separately on Pro
Dimensions · weight
86 × 184 × 30 mm. Pro and Essentials be different hulls: Essentials is 58 × 140 × 30 mm. Both released data sheets print 150 × 67 × 30 mm and 204 g fer both products, which cannot be true o' two different enclosures; the sheets are bein' reissued
Operatin' environment
Indoor use only, no open decks · 0°C (32°F) to 35°C (95°F) · 30% to 70% RH ambient
Storage environment
-20°C (-4°F) up to 65°C (149°F) · 10% to 90% RH while stowed
Regulatory
FCC (USA) · UL (USA/Canada) · CB Scheme / IECEE (international waters) · UKCA (UK) · CE (EU) · RoHS (EU) · SCIP (EU)
Radical transparency be the policy: part numbers, RAM, an' the video pipeline be published right here, not discovered in a teardown.
How many people can share at the same time on Polaris Pro?
Around 10 live sources, composited side by side and laid out automatically as sources join and leave. The ceiling is memory on the chassis, not a license: nothing in the software counts sources or refuses one.
Does Polaris Pro support wireless BYOM?
Yes. The room's camera and microphone attach to the pod over USB, and the pod bridges them into a Teams, Zoom, Webex or Meet call brought in from a laptop. Link is a software bridge between the laptop in BYOM and the Pro, and the Pro is what controls the room's cameras and peripherals. That is why Link needs a Pro.
What is the difference between Polaris Pro and Polaris Essentials?
Essentials runs the same Polaris software as Pro: the same workspace, the same cloud, the same security posture. The differences are the chassis, not the platform.
Essentials: one HDMI output, no HDMI input, no USB, no audio out. Pro: dual HDMI output, HDMI input, 2x USB 3.0 Type-C host, analog audio out.
Can a guest share from another network without a VPN?
Yes. Cross-network sharing is included on every Polaris tier. Cloud-negotiated direct connections, with outbound-only TLS signaling on TCP 443: no VPN, and no inbound firewall rule.
Yes. Polaris Pro has an HDMI input. An HDMI source joins the workspace as a tile by default. Direct bypass takes the glass full screen and keeps that feed in the room.
Pro carries on from Mersive Solstice Gen 3. Same lineage: yer rooms, workflows, an' muscle memory carry forward with ye, an' a mixed Gen 3 + Polaris fleet be fully supported while ye make the passage. The transition path, matey →
See it in yer own rooms
Hardware trials set sail fer every product, straight from Mersive. When the rooms prove it, we introduce yer regional partner fer the rollout.
Rogue signals be jammin' the airspace above the room. Ye're the pod — clear the channel. Jammers rain static, splitters multiply, and every fourth wave the FIREWALL sweeps in. Downed signals drop powered displays: relay shield, dual beam, the piercin' LANCE and the wide-angle SWEEP.
signals cleared: 0 · wave: 1 · link integrity: 3 · best yet: 0
Jupiter · workspace riggin'
WORKSPACE STACK
Shares keep comin'. Compose the workspace — complete a row and it renders to the display. Hold a piece fer later, trust the ghost, and slam it home when ye're sure.
score: 0 · lines: 0 · level: 1 · best yet: 0
Mars · canyon relay
RELAY RUN
Aliens are looting Earth's audiovisual gear, and someone has to invoice them for it. You're the AV Integrator: fight through three decks of their freighter, shoot the capsules open, and take the equipment back — HDMI becomes a Blaster, a Display fans into Multicast, Coil fires Fiber, a Speaker is pure Subwoofer. Switches level your weapon, Surges take one hit for you. Snatchers steal; make them regret it. A boss holds every deck.
score: 0 · mission: 1/3 · best: 0
Pluto · deep-network upkeep
PACKET MUNCHER
Somethin' be nestin' in the farthest switch fabric. Run the corridors, eat every stray packet, and mind the four interference glyphs — each hunts its own way. Grab a powered display and, fer a few seconds, the hunters become the hunted. Ten sectors between ye and a clean network.
score: 0 · sector: 1/10 · lives: 3 · best yet: 0
Venus · the broadcast campus
SIGNAL JUMPER
Ten displays across the broadcast campus went dark, and the interference be strollin' about like it owns the place. Run the loadin' dock, the cable trench, the rooftop, the mezzanine and the antenna tower, then push on through the uplink yard, the static fields, the rack canyon, the microwave bridge and master control — stomp the glyphs flat, bank the signal bits, bump the cache blocks, plant the midpoint flag, ride the ferries, and touch every display back to Polaris green. Game over offers a CONTINUE from the top o' the level that beat ye.
The campus's flagship display was stolen and walled up in a fortress beyond the north-east mesa. Cross a hundred screens o' field, woods, river and dead server yard, crimper in hand — find the two small keys, mind the spikes, arrows and false floors, put five strikes into the CRT TYRANT's open screen, and raise the display where it belongs. Five hollow caves hide heart containers, and the RELAY TOWER on the south-west shore keeps the MERSIVE POLARIS — press X to grab what's in front o' ye, or to send the puck flyin' out and back.
The dongle users be pourin' out o' the rings in formation: HDMI drones, button wingmen, and the big conference pucks runnin' the show. Hold the line in the Polaris fighter. They swoop in, regroup, breathe, and dive. Mind the boss pucks' PAIRING BEAM — get caught and yer fighter is theirs. Shoot that boss down mid-dive and yer fighter comes home to fly beside ye: DUAL FIRE. Every fourth wave be a demo stage — pure flyin', pure bonus, PERFECT if ye drop every last one.
score: 0 · wave: 1 · lives: 3 · best yet: 0
Mercury · the night side run
SOLAR CIRCUIT
A run cut across Mercury's night side, Point A to Point B, against the clock. The sun never sets here and never rises either — it just sits on the horizon throwin' its corona up the sky, and everythin' ye can see is either lit by it or hidin' from it. The route opens wide and fast, closes to a canyon barely three lanes across, climbs, and falls away again, four stages of it. Keep it on the basalt: the regolith either side will drag ye down and take yer speed with it. Stay clean and the craft keeps findin' more — the longer ye hold the line, the faster it'll let ye go, and the yellow pads be how ye get there sooner.